SupeResTM Series has
set a high standard for general organic GPC column category. The columns are
packed with highly porous but hard Styrene-Divinylbenzene gel with remarkable narrow particle size
distribution. The optimization of particle size, porosity and gel material has
resulted in a perfect combination of high resolution and durability. SupeResTM columns can be
shipped in Tetrahydrofuran (THF), Chloroform or Dimethylformamide (DMF). SupeResTM columns are
compatible with a range of common polar and non-polar organic solvents and can
be used for a wide variety of polymers. The columns are available in Single
Pore for known molecular weight rage and Mixed Bed for general scouting
applications.
Part Number
|
Type
|
Exclusion Limit (MW PS)
|
Dimension (mm)
|
Particle Size (nm)
|
Plate Count
|
SINGLE PORE SERIES
|
|
|
|
|
PAS-101
|
Single Pore
|
1.5 × 103
|
8 × 300
|
6
|
>18,000
|
PAS-102
|
Single Pore
|
5.0 × 103
|
8 × 300
|
6
|
>18,000
|
PAS-102.5
|
Single Pore
|
20 × 103
|
8 × 300
|
6
|
>18,000
|
PAS-103
|
Single Pore
|
70 × 103
|
8 × 300
|
6
|
>18,000
|
PAS-104
|
Single Pore
|
400 × 103
|
8 × 300
|
7
|
>18,000
|
PAS-105
|
Single Pore
|
4 × 106
|
8 × 300
|
10
|
>11,000
|
PAS-106
|
Single Pore
|
20 × 106 †
|
8 × 300
|
10
|
>11,000
|
PAS-107
|
Single Pore
|
200 × 106 †
|
8 × 300
|
18
|
>6,000
|
LINEAR MIXED BED SERIES
|
|
|
|
|
PAS-103-L
|
Linear
|
70 × 103
|
8 × 300
|
6
|
>18,000
|
PAS-104-L
|
Linear
|
400 × 103
|
8 × 300
|
7
|
>18,000
|
PAS-105-L
|
Linear
|
4 × 106
|
8 × 300
|
10
|
>11,000
|
PAS-106-L
|
Linear
|
20 × 106 †
|
8 × 300
|
10
|
>11,000
|
PAS-107-L
|
Linear
|
200 × 106 †
|
8 × 300
|
18
|
>6,000
|
| Guard Column
|
|
|
|
|
PAS-G
|
Guard
|
-
|
6 × 50
|
10
|
-
|
| † Estimated. |
|
| |
|
| Temperature Range: |
Ambient
– 60 oC
|
| Maximum Flow Rate: |
2
mL/min
|
| Recommended Flow Rate: |
0.5-1
mL/min
|
| Maximum
Pressure: |
3.5
MPa or 500 psi |
SupeResTM Columns are
also available in Preparative Mode:
Part Number
|
Type
|
Dimension (mm)
|
Particle Size (nm)
|
Plate Count
|
Standard Column
|
PAS-1001
|
Preparative
|
20 x 300
|
6
|
>18,000
|
PAS-101
|
PAS-1002
|
Preparative
|
20 x 300
|
6
|
>18,000
|
PAS-102
|
PAS-1002.5
|
Preparative
|
20 x 300
|
6
|
>18,000
|
PAS-102.5
|
PAS-1003
|
Preparative
|
20 x 300
|
6
|
>18,000
|
PAS-103
|
PAS-1004
|
Preparative
|
20 x 300
|
7
|
>14,000
|
PAS-104
|
PAS-1005
|
Preparative
|
20 x 300
|
10
|
>10,000
|
PAS-105
|
PAS-1006
|
Preparative
|
20 x 300
|
10
|
>10,000
|
PAS-106
|
PAS-1006-L
|
Preparative
|
20 x 300
|
10
|
>10,000
|
PAS-106-L
|
Maximum Flow Rate: 4.5mL/min
Maximum Pressure: 2.0
MPa
Maximum Temperature: 60oC
|
HiTempTM Series are
designed to withstand high temperatures for Polyolefin applications while
providing high degree of separation. The columns are packed with proprietary Styrene-Divinylbenzene gel with
narrow particle size distribution. HiTempTM columns are shipped in Toluene
and are compatible with a wide range of common polyolefin solvents. The columns
are available in Single Pore for known molecular weight rage and Mixed Bed for
general scouting applications.
Part Number
|
Type
|
Exclusion Limit (MW PS)
|
Dimension (mm)
|
Particle Size (nm)
|
Plate Count
|
SINGLE PORE SERIES
|
|
|
|
|
PAHT-303
|
Single Pore
|
70 × 103
|
8 × 300
|
13
|
>7,000
|
PAHT-304
|
Single Pore
|
400 × 103
|
8 × 300
|
13
|
>7,000
|
PAHT-305
|
Single Pore
|
4 × 106
|
8 × 300
|
13
|
>7,000
|
PAHT-306
|
Single Pore
|
20 × 106 †
|
8 × 300
|
13
|
>7,000
|
PAHT-307
|
Single Pore
|
200 × 106 †
|
8 × 300
|
18
|
>4,000
|
MIXED BED SERIES
|
|
|
|
|
PAHT-M
|
Mixed Bed
|
20 × 106 †
|
8 × 300
|
13
|
>7,000
|
PAUHT-M‡
|
Mixed Bed
|
20 × 106 †
|
8 × 300
|
30
|
>4,400
|
| Guard Column
|
|
|
|
|
PAHT-G
|
Guard
|
-
|
6 × 50
|
13
|
-
|
| † Estimated.
|
|
| ‡ Maximum Temperature of
210 oC.
|
|
| |
|
| Temperature Range: |
Ambient
– 140 oC with PAUHT-M up to 210 oC
|
| Maximum Flow Rate: |
1.5
mL/min
|
| Recommended Flow Rate:
|
0.5-1
mL/min
|
| Maximum
Pressure: |
1.5
MPa or 225 psi |

With its strong hydrogen bonding
properties, low viscosity and low refractive index, Hexafluoro Isopropanol
(HFIPA) is ideal for characterization of engineering plastics such as
Polyethylene Trephthalate (PET) and Polyamides (Nylons).HFIPA Series are designed to
withstand high polarity and high acidity of HFIPA while maintaining high degree
of separation. The columns are packed with proprietary packing gel with narrow
particle size distribution. HFIPA columns are shipped in HFIPA and are NOT compatible
other solvents. The columns are available in Single Pore for known molecular
weight rage and Mixed Bed for general scouting applications.
Part Number
|
Type
|
Exclusion Limit (MW PMMA)
|
Dimension (mm)
|
Particle Size (nm)
|
Plate Count
|
SINGLE PORE SERIES
|
|
|
|
|
PAHFIPA-603
|
Single Pore
|
30 × 103
|
8 × 300
|
10
|
>12,000
|
PAHFIPA-604
|
Single Pore
|
100 × 103
|
8 × 300
|
7
|
>12,000
|
PAHFIPA-605
|
Single Pore
|
1 × 106
|
8 × 300
|
10
|
>10,000
|
PAHFIPA-606
|
Single Pore
|
10 × 106 †
|
8 × 300
|
10
|
>10,000
|
PAHFIPA-607
|
Single Pore
|
100 × 106 †
|
8 × 300
|
18
|
>4,000
|
MIXED BED SERIES
|
|
|
|
|
PAHFIPA-M
|
Mixed Bed
|
10 × 106 †
|
8 × 300
|
10
|
>10,000
|
| Guard Column
|
|
|
|
|
PAHFIPA-G
|
Guard
|
-
|
6 × 50
|
15
|
-
|
| † Estimated.
|
|
| |
|
| Temperature Range: |
Ambient
– 50 oC |
| Maximum Flow Rate:
|
1.5
mL/min
|
| Recommended Flow Rate:
|
0.5-1
mL/min
|
| Maximum
Pressure:
|
4
MPa or 580 psi |
Other Specialty
Organic GPC/SEC Columns
In addition to the general columns PolyAnalytik provides
specialized GPC/SEC columns for EXTREME applications such as ionically-charged
packing for high polar and non-polar polymers, and multiple-solvent packing for
constant solvent exchange. Please contact our staff to obtain more information.
|