PolyAnalytik
PolyAnalytik PolyAnalytik PolyAnalytik PolyAnalytik PolyAnalytik
PolyAnalytik
 
info@PolyAnalytik.com
 
Organic Columns
   Organic GPC/SEC/GFC Columns

SupeRes

SupeResTM Series has set a high standard for general organic GPC column category. The columns are packed with highly porous but hard Styrene-Divinylbenzene gel with remarkable narrow particle size distribution. The optimization of particle size, porosity and gel material has resulted in a perfect combination of high resolution and durability. SupeResTM columns can be shipped in Tetrahydrofuran (THF), Chloroform or Dimethylformamide (DMF). SupeResTM columns are compatible with a range of common polar and non-polar organic solvents and can be used for a wide variety of polymers. The columns are available in Single Pore for known molecular weight rage and Mixed Bed for general scouting applications.

Part Number

Type

Exclusion Limit (MW PS)

Dimension (mm)

Particle Size  (nm)

Plate Count

SINGLE PORE SERIES

 

 

 

 

PAS-101

Single Pore

1.5 × 103

8 × 300

6

>18,000

PAS-102

Single Pore

5.0 × 103

8 × 300

6

>18,000

PAS-102.5

Single Pore

20 × 103

8 × 300

6

>18,000

PAS-103

Single Pore

70 × 103

8 × 300

6

>18,000

PAS-104

Single Pore

400 × 103

8 × 300

7

>18,000

PAS-105

Single Pore

4 × 106

8 × 300

10

>11,000

PAS-106

Single Pore

20 × 106

8 × 300

10

>11,000

PAS-107

Single Pore

200 × 106 †

8 × 300

18

>6,000

LINEAR MIXED BED SERIES

 

 

 

 

PAS-103-L

Linear

70 × 103

8 × 300

6

>18,000

PAS-104-L

Linear

400 × 103

8 × 300

7

>18,000

PAS-105-L

Linear

4 × 106

8 × 300

10

>11,000

PAS-106-L

Linear

20 × 106 †

8 × 300

10

>11,000

PAS-107-L

Linear

200 × 106 †

8 × 300

18

>6,000

Guard Column  

 

 

 

 

PAS-G

Guard

-

6 × 50

10

-

† Estimated.
 
Temperature Range:  Ambient – 60 oC
 Maximum Flow Rate: 2 mL/min
Recommended Flow Rate: 0.5-1 mL/min
Maximum Pressure:  3.5 MPa or 500 psi

 SupeResTM Columns are also available in Preparative Mode:

Part Number

Type

Dimension (mm)

Particle Size (nm)

Plate Count

Standard Column

PAS-1001

Preparative

20 x 300

6

>18,000

PAS-101

PAS-1002

Preparative

20 x 300

6

>18,000

PAS-102

PAS-1002.5

Preparative

20 x 300

6

>18,000

PAS-102.5

PAS-1003

Preparative

20 x 300

6

>18,000

PAS-103

PAS-1004

Preparative

20 x 300

7

>14,000

PAS-104

PAS-1005

Preparative

20 x 300

10

>10,000

PAS-105

PAS-1006

Preparative

20 x 300

10

>10,000

PAS-106

PAS-1006-L

Preparative

20 x 300

10

>10,000

PAS-106-L

Maximum Flow Rate:                   4.5mL/min
Maximum Pressure:                     2.0 MPa
Maximum Temperature:               60oC


HiTemp

HiTempTM Series are designed to withstand high temperatures for Polyolefin applications while providing high degree of separation. The columns are packed with proprietary Styrene-Divinylbenzene gel with narrow particle size distribution. HiTempTM columns are shipped in Toluene and are compatible with a wide range of common polyolefin solvents. The columns are available in Single Pore for known molecular weight rage and Mixed Bed for general scouting applications.

Part Number

Type

Exclusion Limit (MW PS)

Dimension (mm)

Particle Size (nm)

Plate Count

SINGLE PORE SERIES

 

 

 

 

PAHT-303

Single Pore

70 × 103

8 × 300

13

>7,000

PAHT-304

Single Pore

400 × 103

8 × 300

13

>7,000

PAHT-305

Single Pore

4 × 106

8 × 300

13

>7,000

PAHT-306

Single Pore

20 × 106 †

8 × 300

13

>7,000

PAHT-307

Single Pore

200 × 106 †

8 × 300

18

>4,000

MIXED BED SERIES

 

 

 

 

PAHT-M

Mixed Bed

20 × 106 †

8 × 300

13

>7,000

PAUHT-M

Mixed Bed

20 × 106 †

8 × 300

30

>4,400

Guard Column  

 

 

 

 

PAHT-G

Guard

-

6 × 50

13

-

† Estimated.  
‡ Maximum Temperature of 210 oC.  
   
Temperature Range:    Ambient – 140 oC with PAUHT-M up to 210 oC
Maximum Flow Rate: 1.5 mL/min
Recommended Flow Rate:          0.5-1 mL/min
Maximum Pressure: 1.5 MPa or 225 psi

HFIPA

With its strong hydrogen bonding properties, low viscosity and low refractive index, Hexafluoro Isopropanol (HFIPA) is ideal for characterization of engineering plastics such as Polyethylene Trephthalate (PET) and Polyamides (Nylons).HFIPA Series are designed to withstand high polarity and high acidity of HFIPA while maintaining high degree of separation. The columns are packed with proprietary packing gel with narrow particle size distribution. HFIPA columns are shipped in HFIPA and are NOT compatible other solvents. The columns are available in Single Pore for known molecular weight rage and Mixed Bed for general scouting applications.

Part Number

Type

Exclusion Limit (MW PMMA)

Dimension (mm)

Particle Size (nm)

Plate Count

SINGLE PORE SERIES

 

 

 

 

PAHFIPA-603

Single Pore

30 × 103

8 × 300

10

>12,000

PAHFIPA-604

Single Pore

100 × 103

8 × 300

7

>12,000

PAHFIPA-605

Single Pore

1 × 106

8 × 300

10

>10,000

PAHFIPA-606

Single Pore

10 × 106 †

8 × 300

10

>10,000

PAHFIPA-607

Single Pore

100 × 106 †

8 × 300

18

>4,000

MIXED BED SERIES

 

 

 

 

PAHFIPA-M

Mixed Bed

10 × 106 †

8 × 300

10

>10,000

Guard Column  

 

 

 

 

PAHFIPA-G

Guard

-

6 × 50

15

-

† Estimated.  
   
Temperature Range: Ambient – 50 oC
Maximum Flow Rate:                  1.5 mL/min
Recommended Flow Rate:         0.5-1 mL/min
Maximum Pressure:                     4 MPa or 580 psi

Other Specialty Organic GPC/SEC Columns

In addition to the general columns PolyAnalytik provides specialized GPC/SEC columns for EXTREME applications such as ionically-charged packing for high polar and non-polar polymers, and multiple-solvent packing for constant solvent exchange. Please contact our staff to obtain more information.

 

PolyAnalytik
PolyAnalytik [Home] [About Us] [Sample Analysis] [System Validation] [Method Development]
[Consultation] [Instrumentation] [Products] [Downloads] [Privacy] [Contact Us] [Request a Quote]
Copyright © 2006-09 Polyanalytik.com PolyAnalytik
PolyAnalytik